Get more heat out of the loop you already have. G FLUID™ goes into your existing water-based coolant and helps it carry heat away faster.
Patent pending.
Graphene improves heat transfer in your coolant, so the fluid carries more heat away.
G FLUID™ is water-based and made for existing coolant loops. No redesign, no new hardware.
Not classified as hazardous under the Globally Harmonised System as adopted in Australia. Not a dangerous good for transport.
We’re vertically integrated. We make our own graphene from methane gas and formulate our own graphene-enhanced products, so we control quality and supply.
Tested to EN 1276, G FLUID™ reduces microbial growth in your coolant loop, so systems stay cleaner for longer.
See how G FLUID™ and THERMAL-XR® work together across the cooling loop, pairing coolant-side heat transfer with surface-side thermal performance.
When your heat load climbs, your usual options get expensive fast – bigger pumps, more coils, another chiller. G FLUID™ gives you a simpler place to start. Add it to your water-based coolant and it gets better at moving heat – up to 20% faster – so you get more from the equipment you already run.
Graphene improves heat transfer in your coolant, so the fluid carries more heat away.
G FLUID™ is water-based and made for existing coolant loops. No redesign, no new hardware.
Not classified as hazardous under the Globally Harmonised System as adopted in Australia. Not a dangerous good for transport.
We’re vertically integrated. We make our own graphene from methane gas and formulate our own graphene-enhanced products, so we control quality and supply.
Black colour doubles as a visual dose and leak indicator, so you can spot issues at a glance.
Talk to us about your data centre cooling, closed-loop systems, and whether G FLUID™ is a fit.
Designed for water-based cooling systems, including:
Tested against untreated PG25 coolant
| Parameter | Test method / standard | PG25 baseline (current) | GMG G FLUID™ additive (result) |
|---|---|---|---|
| Base fluid type | — | 75% water + 25% propylene glycol | PG25 + 1% G FLUID™ |
| Colour | Visual assessment | — | Black – visual dose / leak indicator |
| Thermal conductivity (k) | ASTM D7896 (Transient Hot Wire) | 0.64 W/m·K | 0.69 W/m·K (7% improvement) |
| Heat transfer COEFFICIENT | Lab test using DI water | N/A | ~20% higher heat transfer coef. |
| Viscosity @ 40°C | ASTM D445 | ~1.5 cSt | ~1.5 cSt (comparable) |
| pH of solution | ASTM E70 | 6.5-7.5 | 6.5-7.5 |
| Flash point | ASTM D92/D93 | N/A (water-based) | N/A (water-based) |
| Graphene / nano loading | Gravimetric / TGA | N/A | 0.01% in final mix |
| Colloidal stability (24h) | Visual / centrifuge | N/A (no particles) | Stable – no visible agglomeration |
| Clogging risk | — | None (dissolved) | None (dissolved) |
| Loop applicability | — | Primary / Secondary | Both |
| Acute oral toxicity | OECD 423 or equiv.* | Low (food-grade PG) | Low (water-based system) |
| Long-term sedimentation (30 days / 6 months / 1 year) | Centrifugal test | N/A | Stable at 1790xG for 10 mins (@ 4000 rpm) |
| Organism | Test standard | Microbial Reduction |
|---|---|---|
| Staphylococcus aureus (ATCC 6538) | EN 1276 | 84.2% |
| Escherichia coli (ATCC 10538) | EN 1276 | 60.2% |
| Pseudomonas aeruginosa (ATCC 15442) | EN 1276 | 87.4% |
| Enterococcus hirae (ATCC 10541) | EN 1276 | 50.1% |
| Microbacterium sp. | EN 1276 | 50.0% |
| Legionella pneumophila bactericidal activity | EN 1276 | 50.0% |
Dose rate is 1% by volume. Shake well before use – settling may occur. One bottle treats a lot of loop.
| Cooling system volume | 5 L | 15 L | 25 L | 50 L | 75 L | 100 L |
|---|---|---|---|---|---|---|
| G FLUID™ dose | 50 ml | 150 ml | 250 ml | 500 ml | 750 ml | 1000 ml |
From bottle to loop in under a minute
Just like our graphene-enhanced products maximise efficiency, we use cookies to keep this website running at peak performance. These tools help us measure site traffic, secure your connection, and load embedded content such as videos and maps.