THERMAL-XR⁠® CASE STUDY | Thailand, Siam Pharmaceutical, 14.68% Energy Reduction

GMG release

Siam Pharmaceutical Co., Ltd., a pharmaceutical manufacturing and distribution company based in Bangkok, applied THERMAL-XR⁠® graphene coating to an air-cooled chiller and measured a 14.68% reduction in energy use, translating to an estimated saving of 23,218 THB per year and a return on investment of under 1 year.

Case at a glance

CustomerSiam Pharmaceutical Co., Ltd.
LocationThailand
Site typePharmaceutical manufacturing plant
EquipmentAir-Cooled Chiller
BrandCarrier
Capacity9 tons
Model30GTC009
Equipment age19 years
Energy savings14.68%
Annual cost saving23,218 THB/year
Return on investment< 1 year

Background

Air conditioning and chiller systems are a constant electricity cost in pharmaceutical production, where temperature and humidity must be tightly controlled. Over time, condenser coils lose heat transfer efficiency, which forces compressors to work harder and increases energy consumption. At Siam Pharmaceutical, the cooling load is carried by a Carrier air-cooled chiller with a capacity of 9 tons, which has been in service for 19 years.

The solution: THERMAL-XR⁠®

THERMAL-XR⁠® is a graphene-enhanced coating from Graphene Manufacturing Group (GMG), designed to deliver superior heat transfer and protection for heat exchanger coils. The coating was spray-applied to the condenser coils of the air-cooled chiller, with no change to the equipment itself.

Results

Energy use was compared before and after coating:

  • Electricity usage: 92 kWh/day before coating vs 78 kWh/day after
  • Electricity cost: 13,180 THB/month before coating vs 11,245 THB/month after
  • Carbon emissions: 15 tons CO2/year before coating vs 13 tons CO2/year after
  • Annual saving: 23,218 THB per year
  • ROI: < 1 year

These results equal an energy saving of 14.68%.

Takeaway

The Siam Pharmaceutical case shows that THERMAL-XR⁠® can restore efficiency even on very old equipment: on a chiller that has been running for 19 years, the coating cut energy use by nearly 15% and paid for itself in under a year.

Want similar results at your site?

Get in touch with GMG to discuss your cooling equipment, or find a THERMAL-XR⁠® applicator near you.

Measured energy savings presented in this case study are not predictors of future installation results. Estimated savings should be considered as estimates. Standard GMG disclaimer applies. All contents copyright © Graphene Manufacturing Group Ltd. All rights reserved.